Инструкция по эксплуатации к двигателю 4G64 S4M (english)

Contents

Chapter 1 Main Technical Characteristics of 4G64 S4 Engine
      Characteristic Parameters
Chapter 2 Usage and Maintenance of 4G64 S4 Engine
      Usage and Maintenance Part 1, Usage and Maintenance Part 2, Forbidden Items
Chapter 3 Diagnose and Treatment of Common Faults


Chapter 2 Usage and Maintenance of 4G64 S4 Engine


1. Precautions of Usage

(1)     When using, please modulate, maintain it according to the maintenance method and each regulation introduced by this introduction manual, and consult it with the inspection manual of the operation instructions.

(2)     Check bolding polarity of the storage battery. This gasoline engine adopts cathode bonding.

(3)     Before starting the engine, check whether the cooling liquid in the radiator reaches the highest mark. If it is not, fill it up based on what it is needed. Meanwhile, check the oil level of the machine oil of the engine and fill it to the required position based on what it is needed.

(4)     Before starting the engine, each starting time of the starter should be no more than 5 seconds. Consecutive start is normally no more than 5 seconds. And each two pitch time should be no less than 15 seconds.

(5)     When using the new machine, it should be worn in based on the prescription. It is not allowed to accelerate suddenly or add burden.

(8) Keep the normal water temperature at 85-105°C.

(7)     The fuel must be the RON>93 number high quality unleaded gas.

(8)     When the engine is working, especially with the high speed and high burden, it is not allowed to stop immediately. Under the low speed state, it should stop after operating for 3-5 minutes in order to make the heat emission of the engine evenly.

(9) The machine oil of required level and stickiness should be used.

(10) It li only after the reduction of water temperature that the radiator cover can be opened to check whether it is shortage of the cooling water. Otherwise, the hot water will be splashed out, which will cause being scalded. When letting out the cooling water of the cooling pump, radiator cover should only be opened after the reduction of the water temperature. Then open the water drain valve under the radiator and drain plug at the right back of the cylinder body.

2. Start, Operation and Stop of Engine

Using the engine correctly, will not only keep the engine running normally, but also extend the lift span of the engine.

2.1 Preparations before Starting

The followings should be checked before starting the engine:

(1)     Check the height of the liquid level of the cooling liquid, degree of fixture of water pipe connection and the degree of tightness of the radiator.

(2)     Check whether the amount of the machine oil displayed by the machine oil rule meets the requirements.

(3)     Check whether each pipeline and connection of the oil supply system are reliable and

                 Operation Instructions of the 4G64 S4 MPI Englhe

eliminate the air and the phenomenon of false connection. (4) Check the fixture degree of each connecting terminal of electric equipments, such as the electrical machine, starter, ignition plug and sparking coil.

2.2    Starting Steps

(1)     Firstly, place the changer level of the speed changer on the neutral position.

(2)     Step on the clutch to reduce the burden when starting the engine.

(3)     Turn the key to the ignition switch and place it on the starting position. Each starting time of the starter should be no more than 15 seconds. The consecutive starting should be no more than 15 seconds. Every two pitch time should be no less than 15 seconds.

(4)     After staring the engine, release the key to the ignition switch immediately to make it go to the ignition position automatically. If it cannot start after starting the engine several times (The consecutive starting is normally no more than 5 times.), please find out the reason and eliminate it.

2.3    Check during its operating

(1)     Whether there is abnormal noise like knock, backfire or whack.

(2)     Whether there is unusual odor when the electrical machine or other electric equipments and wire harness are too hot

(3)     Whether each fuel, cooling, lubricating system are leaking out.

(4)     Whether the readings of instruments like the pressure of the machine oil, water temperature and amount of gasoline are normal.

2.4    Stop operating

When the engine is working loaded with the heavy burden, If It needs to stop working, firstly idly run 2-3 minutes at a idle speed, then shut down the ignition switch and stop working to prevent the distortion of some parts caused by the sudden cooling. In winter, let out cooling water of the engine (Do not let out if antifreeze is used.). When letting out water, open the filler cap of the radiator (or the secondary water tank), and open the drain switch under the radiator and at the left side of the cylinder body. Leave only after letting out all water.

3.    Wearin of New Engine

(1)     Firstly check whether the machine oil, cooling liquid and gasoline are enough. If they are not enough, renew and eliminate them.

(2)     The performance and life span of the engine have a close relationship with the service modes at the initial stage. The new or newly installed engine should be carried out wearin according the breaking in criterion on the car. Drive it carefully during the wearin period.

(3)    When breaking in, the car should be driven at the cement or asphalt road. Try not to drive on the other roads especially the sand beach.